Click to open expanded view

E2000/APC-E2000/APC Fiber Patch Cord Simplex SM E9 OS2 FRNC I-V(ZN)HH Fig.O 5m Yellow

Product Details

GigaLine patchcord, LSH/APC - LSH/APC, I-V(ZN)HH 2E9/125µ OS2, FRNC-yellow, Length: 5,0m, test report incl.

KERPEN DATACOM

LKD9A1301000000

TP033774

DPX LSH/APC-LSH/APC MP 5,0 OV

New

Product Description

The E2000/APC-E2000/APC Fiber Patch Cord Simplex SM E9 OS2 FRNC I-V(ZN)HH Fig.O 5m Yellow (Part number: LKD9A1301000000) from KERPEN DATACOM is a Simplex patch cord with E2000/APC connector at one side and a E2000/APC connector at the other one. Fiber patch cords are a type of cables that have two connectors on both ends. Optic patch cords can come in simplex (1 fiber), duplex (2 fibers) or in MPO (12 fibers). The connectors on both sides of the patch cord, allow it to be quickly connected to another device such as an optical switch or other telecommunications/computer device.

Fibre optic patchcord with additional outer sheath

Characteristics

  • For applications in data center, office and industry
Need more information about this or other related products? We have more Fiber Optics | Patch Cords solutions for you. Contact us.
Customers also search by: Fiber Patch Cord, Fiber Optic Patch Cord, Fiber Patch Lead

Product Specifications

Jacket Material
FRNC
Configuration
Simplex
FO Connector Type 1
E2000
FO Polish Connector 1
APC
FO Connector Type 2
E2000
FO Polish Connector 2
APC
Color
Yellow
Lengths
5m

Jacket Material - FRNC

FRNC (flame-retardant, non-corrosive) is a jacket material that is designed to limit the spread of fire and reduce the emission of toxic fumes. It is used in environments where safety is a primary concern, such as hospitals, schools, and public buildings. FRNC is highly resistant to moisture and chemicals, making it suitable for harsh environments. It is also non-corrosive, which means it will not degrade over time or cause damage to other materials. However, it may be more expensive than other cable jacket materials.

Configuration - Simplex

A Simplex configuration is a type of cabling arrangement commonly used in data centers and telecommunication networks. It consists of a single cable , terminated with a connector at each end. It is normally used in Half Duplex or Full Duplex data transmitions.

FO Connector Type 1 - E2000

The E2000 FO Connector or LSH is a type of fiber optic connector that uses a 2.5mm ceramic ferrule to align and connect optical fibers. Used in high-speed data communication networks. Provides low insertion loss and high return loss. The push-pull latching mechanism allows for easy and secure connections, while the dust cap protects the connector from contamination and laser beam protection. The E2000 FO Connector is commonly used in telecommunications, data centers, and other high-performance and high power applications.

FO Polish Connector 1 - APC

APC (Angled Physical Contact) FO Polish Connector Type 1 is a fiber optic connector that uses an angled endface to achieve low back reflection and insertion loss. It features a 1.25mm ceramic ferrule and is commonly used in telecommunications and data networking applications where low back reflection is critical. The APC connector offers high precision and reliability, making it suitable for use in single-mode fiber networks. However, the angled endface of the APC connector requires special polishing techniques, making it more expensive than other connector types.

Complementary Products

Visited Products